Get two or three written quotes and check each one against the same ten questions, so you're comparing the same job and not just the bottom line. Anything a quote leaves out is a question to ask before you sign. The HouseExhale app checks quotes against the same ten.
Start with two or three written quotes
More than one quote shows you the range of designs and prices for your house. The FTC advises getting multiple estimates that describe the work, materials, completion date, and price. Electrify PDX, writing about heat pumps, suggests at least three, even if you have a contractor you've used before.
Ask that each quote be itemized, with equipment and labor listed separately. EnergySage makes the point that comparing quotes on the total alone isn't the best way to find the right fit, and that a big difference in price is a reason to ask each contractor why. If a quote for ducts to every bedroom comes in far below about $4,000, ask what it leaves out. What drives the cost has planning ranges by layout.
The ten questions every quote should answer
- Names the exact unit (brand and model). Which exact model will they install, what is its HVI-certified airflow at the duct pressure they expect, and what is its heat recovery at 32°F? "HRV" or "ERV" alone isn't enough. EnergySage recommends asking for the model number if a quote leaves it out, and with it you can look up the specs and the manual yourself. If it's one of the units we've reviewed, its page has the certified airflow, the maker's documents, and a check against your bedrooms.
- Fresh air to each bedroom, in cfm. How much fresh air will each bedroom get on the normal setting? For the goal of 800 ppm or less while you sleep, that's about 17 cfm per person sleeping there, so about 34 cfm for two (getting a bedroom to 800 explains the number). Ask where stale air is pulled from, usually bathrooms and the laundry, and how air leaves a bedroom when the door is shut. The Building America checklist calls for each occupied room with a door to have at least one ducted supply or return.
- Measured and balanced within 10%. Will they measure supply, exhaust and every room after the install, and balance supply and exhaust to within about 10% of each other? Which device will they use: a flow hood, a flow grid, or the unit's built-in ports read with a gauge? The 10% figure comes from codes such as Washington's and Minnesota's. One manual we checked allows up to 10% more exhaust than supply in cold climates, so if they set the two apart on purpose, ask which way and why, and have it written down.
- Signed airflow sheet. Will you get a signed sheet with those airflows, a label on the unit with them, and any test report the code requires? Where the 2021 energy code is in force, a signed airflow test report goes to the building department. The sheet is your proof of what the system delivered on day one.
- Permit, inspections and any airflow test. Is a permit needed, and who pulls it? Are the inspections and any required ventilation airflow test included in the price? The FTC lists a contractor asking you to get the permits yourself as a warning sign.
- Where the outdoor hoods go. Where will the two hoods go, what clearances apply, and how will the hoods be screened and sealed? There's no single number: clearances differ by code and by the unit's manual. Common code wording keeps an exhaust outlet 10 feet from a fresh-air intake unless it sits 3 feet higher, and 3 feet from windows and doors that open. One HRV manual we checked also wants the hoods about 6 feet apart and 18 inches above the ground or snow, with the intake 3 feet from dryer vents, gas meters and driveways. Vermont's code guidance puts the intake at least 12 inches above expected snow.
- Coldest-weather plan and drain. What does the unit do on your coldest nights, and how much fresh air keeps coming in while it defrosts? Does it need a drain, and how is freezing prevented? Models differ a lot. Below 14°F, the temperate version of one compact ERV we checked shuts off for 56 minutes at a time, then checks the temperature and defrosts; its cold-climate version does that only below −22°F, so ask which version you're quoted. One HRV manual we checked requires a drain with a water-filled trap kept where it can't freeze, while that compact ERV needs no drain.
- Controls set and labeled. What controls will you have: normal speed, boost, and any humidity or CO2 control? Will they be labeled and set before the crew leaves? Controls switched off or set wrong are among the most common problems researchers find in new homes (after the install has the numbers).
- Patching and finish repairs. If walls or ceilings get opened to run ducts, who patches, textures, and paints, to what standard, and is that included?
- Labor warranty and a return visit. How long does the installer stand behind the work, in writing, separate from the manufacturer's equipment warranty? If a bedroom still averages over 800 ppm on the normal setting, will they come back to measure and rebalance? Also ask who registers the equipment warranty, and by when: some brands shorten coverage if it isn't registered in time, and one we checked drops from 10 years to 5 after 90 days.
Payment and deposit
HouseExhale's guideline is to put down no more than $1,000 or 10% of the contract up front, whichever is lower. Electrify PDX names the same two caps for heat pump contracts and suggests a written schedule of payments for the rest of the job. The FTC advises never paying the full amount up front and notes that some states limit how much a contractor can ask for as a down payment.

What to ask at the site visit
A good site visit takes time. The installer should look at where the unit would sit, how ducts would reach each bedroom, and where the two outdoor hoods would go. Questions worth asking, beyond the ten above:
- Where will the unit go, and can I reach the filters easily? The Building America checklist says filters should be easy for occupants to get to.
- Will it have its own ducts, or connect to the furnace ducts? If it connects, does the furnace fan have to run whenever the ventilator does, and how will stale air be pulled from the bathrooms?
- Which ventilation rule will you design to for our town, and how much of that air goes to each bedroom? How an HRV or ERV should be sized explains the rules, and why a Manual J isn't one of them.
- Does the price include any utility discount on the unit, and who files the rebate paperwork? In Massachusetts and Connecticut, distributors can take $500 off a qualifying HRV or ERV, and the installer claims it. Does any rebate need approval before work starts? Rebates by state lists what we found where you live.
Also check that the contractor is licensed and insured. The FTC suggests confirming the license with your state or county.
Bring your room report
Your room report is the most useful thing you can hand an installer. It shows which bedroom you measured, how many people slept there, whether the door was open or closed, and what the readings looked like across several nights, including after a free change.
Ask each installer how their design would change those numbers in that room. A design that sends fresh air to the main living area but not to the bedroom you measured may not fix the problem you came in with.
Choosing is not signing
Once you have a favorite, go back to it with every gap from the checklist. Ask for a revised written quote that fills them in. The FTC suggests that the contract include the start and completion dates, any promises made in conversation about scope and cost, and a written statement of your right to cancel within three business days.
It's fine to take your time. A careful installer will expect questions, and the answers you get now are much easier to sort out than disagreements after the walls are closed up.
The quote lists the unit's cfm. Is that what my bedrooms will get?
Not necessarily. Rated airflow falls as duct pressure rises: one 90-cfm-class ERV in HVI's directory is rated at 100 cfm at 0.1 inch of duct pressure and 55 cfm at 0.4 inch. Ask for the design airflow to each bedroom on the normal setting, and for a measured airflow sheet after the install.
This week: Line up your quotes
- Contact two or three installers and ask each for a site visit and a written, itemized quote.
- Bring your room report to every visit and ask how their design would get fresh air into that bedroom.
- Score each quote against the ten questions below, then email each installer a short list of the gaps.
Sources
- Electrify PDX: Tips for a happy heat pump journey: How to request and evaluate heat pump contractor quotes (2025)
- EnergySage: How to compare heat pump quotes
- Federal Trade Commission: How to avoid a home improvement scam
- Building America Solution Center (PNNL): Balanced HRV/ERV checklist
- Natural Resources Canada: Heat recovery ventilators (2012)
- Akimoto et al. (2025), ASHRAE 1837-RP: bedroom ventilation and sleep quality (800 ppm and about 8 L/s per sleeper)
- Washington State Building Code, WAC 51-51-1505: balanced within 10%, tested and signed (effective March 16, 2024)
- Minnesota Rules ch. 1322, R403.5.5: intake within 10% of exhaust (text as of March 2026)
- City of Austin: Mechanical ventilation testing FAQs (2021 IECC R403.6.3 signed test report; undated)
- Fantech: VHR150 HRV installation manual (balancing, hood locations, drain; rev. 2018)
- RenewAire: EV Premium+ ERV installation manual, intake clearances (June 2026)
- Residential Energy Dynamics: Best practices for residential ventilation (code separations for terminations; May 2023)
- Efficiency Vermont: 2020 RBES ventilation installation best practice (intake above expected snow; undated)
- Panasonic Canada: Intelli-Balance 100 sell sheet, French (defrost by model version; undated)
- Bryant: HRVXXSVA heat recovery ventilator, warranty registration terms (product page, checked October 12, 2026)
- Home Ventilating Institute: Section III HRV/ERV directory (airflow at each duct pressure; export of September 23, 2026)
- Mass Save: Instant discounts on qualified residential HVAC equipment (2026)
- Energize CT: ERV-HRV incentives (2026 program year)