What a CO2 monitor can (and can't) tell you about your home

Use CO2 to understand ventilation in an occupied room, with a clear view of what the number leaves out.

Jump to tonight’s step

A CO₂ monitor on a dresser across the bedroom, away from the pillow and window.
Measure the room: keep the monitor away from faces, direct drafts and sun.

At a glance

In this guide 7 sections

A CO2 monitor tells you one thing well: how much outside air is reaching a room while people are in it. It doesn't measure every pollutant, it isn't a mold test, and it isn't a medical test. For a bedroom, there's now a clear number to compare it with: 800 ppm or less, on average, while you sleep.

Why CO2 tracks fresh air

Every time you breathe out, you add a little carbon dioxide (CO2) to the room. Outside air coming in through windows, doors, gaps and ventilation systems dilutes it and carries it away. When a room gets plenty of outside air for the number of people in it, CO2 stays fairly close to outdoor levels. When it doesn't, CO2 builds up.

That makes CO2 a handy stand-in for ventilation. ASHRAE, the engineering society behind US ventilation standards, calls indoor CO2 "at best an indicator of outdoor air ventilation rate per person." The US EPA puts it in similar terms: indoor CO2 can give you information about ventilation, but it needs to be interpreted carefully.

Outdoor air is the starting point. Global outdoor CO2 passed 400 ppm (parts per million) in 2013, according to ASHRAE, and NOAA's monthly average at Mauna Loa was about 426 ppm in September 2026. For everyday purposes, think of outdoor air as about 425 ppm and slowly rising.

A wall-mounted CO alarm on the left and a separate tabletop CO₂ monitor on the right.
CO alarm on the left; CO2 monitor on the right. Neither replaces the other.

What it can't tell you

A CO2 number answers one narrow question, so it has limits.

  • It doesn't measure other pollutants. ASHRAE notes that indoor CO2 is "not necessarily well correlated" with pollutants such as mold, formaldehyde, carbon monoxide and airborne particles. Many of those come from sources that have nothing to do with how many people are in the room, so a room can have low CO2 and still have other air problems.
  • It isn't a mold test. A low reading doesn't mean a room is free of mold, and a high one doesn't mean it has any. Visible mold or a musty smell needs its own investigation.
  • It isn't a carbon monoxide alarm. CO2 and carbon monoxide (CO) are different gases. A CO2 monitor won't warn you about CO from a furnace, water heater or attached garage. The US Consumer Product Safety Commission recommends CO alarms on each level of the home and outside sleeping areas.
  • It isn't a baby monitor. It reads the room's fresh air, not anyone's breathing. In a room where a baby sleeps alone, the reading can stay low even with little fresh air, because estimates put a baby's CO2 output at roughly a quarter of an adult's.
  • It isn't a medical measurement. ASHRAE's position document describes the evidence for direct effects of CO2 itself on health, sleep and performance at commonly observed indoor levels as "inconsistent." Sleep studies link poorly ventilated bedrooms to slightly worse sleep in healthy adults, but that's about the fresh air the number stands for. A CO2 reading describes the room, not the people in it.

The UK Health and Safety Executive (HSE) sums it up well: CO2 measurements are "only a broad guide to ventilation rather than demonstrating 'safe levels'."

CO2, the other things people breathe out, and how you feel

A room's CO2 rises together with everything else people give off from breath and skin. In one chamber study, 25 awake adults spent about four hours in air with pure CO2 added to 1,000 or 3,000 ppm, and it made no significant difference to how they rated the air, their symptoms or their thinking tests. When the same 3,000 ppm came from people in the room, along with everything else they give off, they reported more headache, fatigue and sleepiness. That's one reason researchers read CO2 as a marker of stale air rather than the culprit, and why the fix is more outdoor air.

True CO2 sensors and estimated ones

Not every device that shows a CO2 number actually measures CO2. There are two main kinds.

NDIR sensors (non-dispersive infrared) detect CO2 directly, using the way CO2 absorbs infrared light. HSE recommends NDIR monitors as the most suitable type for checking ventilation. Some newer sensors use a photoacoustic form of NDIR, sometimes labeled PAS. They measure CO2 directly too.

Estimated CO2 sensors measure other gases and calculate a CO2-like number from them. The reading is usually labeled eCO2, CO2eq or "equivalent CO2", often next to a TVOC (total volatile organic compounds) figure. The datasheet for one common chip of this type, Sensirion's SGP30, says its CO2eq signal is calculated from ethanol and hydrogen measurements. Because the number is derived from other gases, it can move for reasons that have nothing to do with fresh air.

If your monitor's box, manual or listing doesn't mention NDIR or photoacoustic, check before you rely on its CO2 readings. HouseExhale's room reports assume a true CO2 sensor.

What the numbers can show you

With a true sensor, two things are worth watching: how far the room climbs above outdoor air while people are in it, and whether that happens night after night. Lower means more outside air per person. Higher means less.

Pattern matters more than the peak. HSE cautions that single or "snapshot" readings can be misleading, because the number changes with how many people are in the room, what they're doing and whether windows or doors are open. A few nights of readings, taken the same way each time, tell you far more than one glance at the screen.

The number to aim for in a bedroom

For a bedroom, aim for 800 ppm or less, averaged over the hours you're asleep. That's the target proposed by the researchers behind a 2025 review of 17 sleep studies carried out for ASHRAE: sleep was slightly but measurably more disturbed once bedroom CO2 reached about 1,000 ppm, and wasn't measurably different at 850 or below. HouseExhale scores each night against that goal. Why 800, and not 1,000 explains the numbers, and the research behind the goal goes study by study.

Getting trustworthy readings

A few habits make any monitor more useful:

  • Keep it at about head height and at least 2 ft (60 cm) from anyone's face, since breath near the sensor pushes the number up.
  • Keep it out of direct drafts from windows, doors and vents.
  • Use the same spot every time, so one night can be compared with the next.
  • Write down who was in the room and whether the door and window were open or shut.
  • Check it against outdoor air now and then. Can I trust my CO2 monitor? shows how.

Do that, and a CO2 monitor answers one question well: is this room getting enough outside air for the people using it?

Tonight: Check what your monitor really measures

  1. Look on the box, manual or product page for NDIR or photoacoustic (PAS). If you only see eCO2, CO2eq or TVOC, the CO2 number is an estimate, not a measurement.
  2. Set the monitor in your bedroom at about head height, at least 2 ft (60 cm) from where anyone's face will be.
  3. Write down the reading when you turn out the light, with the door and window set the way you usually sleep.
  4. In the morning, before you open the door or window, write down the reading again. Compare both numbers with outdoor air (about 425 ppm) and with the bedroom goal of 800 ppm or less.