After the install: proving it worked and keeping it working

Collect the handoff, check the airflow numbers, repeat your bedroom check, and make upkeep part of the routine.

Jump to this week’s step

A ventilation cabinet, a removable filter and an instruction booklet in a utility space.
Follow your model’s manual for filter care, core cleaning and service.

At a glance

In this guide 9 sections

A new HRV or ERV isn't finished when the installer packs up. Collect the right paperwork on install day, check that the airflow numbers make sense, recheck the same bedroom starting two weeks later, and keep the filters and core on a schedule.

Install-day handoff checklist

Before the installer leaves, go through these ten together. The Building America checklist for balanced systems says operation and maintenance should be reviewed with the homeowner, so this is a reasonable thing to ask for. The app's install checklist has the same ten.

  • I have a signed airflow sheet. Fresh air in and stale air out, on the normal setting and on boost, with the device used and the date. Supply and exhaust should be within about 10% of each other, or set apart on purpose with the reason written down. Save a photo under Documents.
  • Each bedroom's airflow is on the sheet. Measured on the normal setting. The goal is about 17 cfm for each person sleeping there (34 for two).
  • The airflows are on a label on the unit. Natural Resources Canada recommends it, so the next technician can see them. Save a photo of the label.
  • I know the normal setting, and it's written down. Photo the control. Have them show you boost and any humidity or CO2 setting. The control should be labeled. Natural Resources Canada recommends running an HRV on low continuously year-round, with high speed for things like cooking, showers, painting, or a full house.
  • I know where the filters are and which ones to buy. The part number, MERV rating and how often to change them are in the manual. Ask for a spare set.
  • I was shown the drain and frost protection. Where the drain and trap are, and what the unit does on the coldest nights, including how much fresh air still comes in. Check that the model on the sheet is the version you were quoted, since some models come in temperate and cold-climate versions.
  • I know where the outdoor hoods are and what to keep clear. The fresh-air intake should sit above the snow line. Keep plants, leaves and snow away from both hoods.
  • Warranty registered, and labor warranty in writing. Some brands shorten the warranty if you don't register in time; one we checked drops from 10 years to 5 after 90 days. Photo the model and serial label.
  • Inspection booked or passed, and any test report saved. Many towns require a signed airflow test report. If your installer says no permit is needed, ask why and save their answer.
  • I know who to call and when the yearly check is due. Natural Resources Canada recommends a yearly service that includes a balance check.

What good airflow numbers look like

The signed sheet should show:

  • Total fresh air at or above the design rate on the normal setting, not only on boost, and at least any code minimum that applies.
  • Supply and exhaust within about 10% of each other. That's the figure Washington's and Minnesota's codes use; California allows 20%. The manuals we read give no number of their own, and one allows up to 10% more exhaust than supply in cold climates. A deliberate offset is fine when the sheet says which way and why.
  • Each bedroom at about 17 cfm per sleeper on the normal setting. That's HouseExhale's bedroom goal, not a code rule.
  • How it was measured: with the unit's built-in ports and a pressure gauge, or a flow hood or flow grid at each grille, plus the device, the date and who measured. In field tests cited by Lawrence Berkeley National Laboratory, powered flow hoods were off by about 6% and unpowered ones by 11% to 25%.
  • Measured under normal conditions: house closed up, clean filters in place, and not while the unit was defrosting.

What "Verified" means in HouseExhale

The app marks your install Verified when both of these are true:

  1. Your bedroom nights pass. At least three recheck nights logged from two weeks after install day, in the room you measured before, with the same number of people, and the door and window set the same way, as a "before" night, and the system on its normal setting, not boost. The median of those nights is at or below 800 ppm. Nights from the first two weeks don't count.
  2. A measured airflow record is saved. The signed airflow sheet, a code test report or a commissioning report, under Documents.

The nights show the bedroom outcome, and the sheet shows the system was set up to deliver it. A good sheet alone can hide a control that was later turned down, and good nights alone don't tell the next technician what the system was set to. If the nights pass but no sheet is saved, the app says so and asks you to get one. If the room is clearly better (by the same margin a free fix has to clear) but not at 800, or no better, it suggests asking for a balancing check.

A monitor, pencil and notebook with spaces for three nights of observations.
The same setup and a short note make nights easier to compare.

Prove it: recheck nights

Log three recheck nights starting about two weeks after install, and one more around three months. Keep everything the same as your "before" nights: the same room, the same people, the door and window set the same way, and the monitor in the same spot. ASHRAE notes that sensor location and calibration are critical for drawing meaningful conclusions from CO2 readings, so moving the monitor can muddy the comparison. Run the system on its normal setting, the one it will use every night.

Run the outdoor check before your before nights and before your after nights. Self-calibrating monitors can drift in a closed room, and drift can look like a change.

The two-week nights tell you whether the system is delivering air to that room. The three-month night shows whether that holds up, often in a different season with different window and door habits. In a cold climate, add a night during a cold spell, since defrost can cut the fresh air on the coldest nights.

The goal is the same as before the install: a typical night of 800 ppm or less, on average, while you sleep.

If the bedroom still reads over 800

Start with the basics, in this order:

  1. Is the unit on, and on the normal setting? Some controls run the unit for part of each hour at a higher speed instead of continuously on low. Find out which one the installer set, and log recheck nights on that setting.
  2. Are the filters clean and both outdoor hoods clear?
  3. Were the nights comparable? Same people, same door and window, same monitor spot.

If all of that checks out, ask the installer for a balancing check, and bring the airflow sheet and your before and after nights from the app so you're both looking at the same evidence. If the sheet shows the bedroom getting about 17 cfm per sleeper and the room still reads high, ask how air leaves the room with the door shut. If the sheet shows less, the design or the balancing gave the room too little air, and a rebalance or a design change is the fix.

What the unit does in very cold weather

When very cold air meets the warm, moist air leaving the house inside the core, frost can form. Natural Resources Canada says most HRVs have an automatic defrost mode that starts when incoming outdoor air drops below about 23°F (−5°C). One method briefly blocks the incoming fresh air and lets warm house air run through the core to melt the frost. Some units use a preheater instead. ERVs need frost protection too, and your manual describes how yours handles it.

As outdoor temperatures fall, defrost cycles get longer. In cold-winter places, including much of Colorado, expect them on the coldest nights. That's normal, not a fault. How much fresh air keeps coming in depends on the model: below 14°F, the temperate version of one compact ERV we checked shuts off for 56 minutes at a time before it checks the temperature again, while its cold-climate version waits until −22°F.

Building Science Corporation notes that in cold climates these systems must be set up to handle condensation. If yours has a condensate drain, Natural Resources Canada suggests checking it and its tubing twice a year to make sure water flows freely, and notes the drain needs a trap. Traps can dry out, so the Canada Mortgage and Housing Corporation suggests pouring water into the drain pan once a year to check it.

What goes wrong in real homes

When researchers visit new homes, the problems are usually simple ones.

What researchers foundThe check that catches it
Systems off. In 70 new California homes, the whole-house system was running in only 18 when researchers arrived.Is it on, and on the normal setting? Ask that first whenever a room misses the goal.
Owners unsure of the controls. Only 11 of 29 Oregon owners and 10 of 26 Colorado owners knew how theirs worked. California systems with a clear, labeled switch were running in 7 of 9 homes.A labeled control, the normal setting written down, and a walkthrough before the crew leaves.
Ducts on the wrong port. One ERV was connected so it only supplied air.Stand at each outdoor hood: one should pull air in and the other push air out.
Clogged filters, and intakes blocked by snow, frost, leaves or plant fluff.Filter reminders and a look at both hoods each season.
Units never balanced, or freezing up. Experts in northern Canada reported widespread freeze-ups, and one estimated that fewer than 1 in 10 local units were properly balanced.Measured balancing on install day, a yearly balance check, and a recheck night in a cold spell.
Drain traps sucked dry.Pour water into the drain pan and check the drain twice a year.

In Building America field data on new homes, 48% met the ASHRAE 62.2 ventilation standard overall and 64% in Colorado, and most failures came from how systems were installed or run. When it works, it helps: a DOE study of 51 newer Southeastern homes found that properly working whole-house ventilation cut CO2 by about 30%.

Keeping it working

  • Filters. The app's default reminder is every three months, and you can set it anywhere from 1 to 12 months. Natural Resources Canada suggests cleaning filters every one to three months, and every three months is the most common interval in the manuals we read; one says to replace them rather than clean them. Your unit's manual has the final word, so set the reminder to match it.
  • The core. Inspect and clean it as your manual directs. Natural Resources Canada suggests inspecting it twice a year and recommends a yearly service by a qualified contractor, including a check that the system is still balanced.
  • Outdoor hoods. Check the intake and exhaust hoods regularly for leaves, plants, or other debris, and for snow in winter.
  • The drain. If there is one, check it twice a year and keep the trap full of water.
  • Seasonal room check. Log a night or two in the same bedroom each season. It's a quick way to catch a clogged filter or a control that got switched off.

If you ever turn the system off, Natural Resources Canada advises making other provisions for ventilation, such as opening windows.

When to call someone

Call your installer if a recheck shows the room is no better than before, if you see water where it shouldn't be, or if the unit is noisy or not running. Bring the airflow sheet and your recheck nights. Together they let the installer compare what was measured on install day with how the room is doing now.

This week: Set up your after-install routine

  1. Photograph the signed airflow sheet, the label on the unit and any code test report, and save them under Documents in the app with your warranty and permit paperwork.
  2. Open the unit with the manual in hand, find the filters, and write down the exact replacement part and how often to change it.
  3. Put recheck nights on your calendar: three nights starting two weeks after install day, and one around three months. In a cold climate, add one during a cold spell.