Made by the ventilator’s makerS&P (Soler & Palau)
S&P SCO2-W
S&P’s adjustable CO2 control, listed for its TRC and TRPLe ventilators.
$781.60 at Ferguson Home (special order); Sylvane’s page lists $852 (October 17, 2026)
- Can be set under 800Under HouseExhale’s 800 ppm goal
- Wall CO2 control for S&P ventilatorsWhat it is
- An installerWho fits it
At a glance
- In its favour: Can be set under 800
- In its favour: Adjustable from 600 to 2,000 ppmSo 750 is in range.
- Worth knowing: S&P lists it for the TRC and TRPLe, not the TReRetailers disagree about which units it fits. Ask S&P about yours.
- Plain fact: Runs on 24 V AC, with a building-automation interface
Setting it for a bedroom
HouseExhale’s setting: switch up at 750 ppm and back at 650, or ramp from 600 to full by 750. Never above 800.
- Set it to 750 ppm.
- Ask S&P, or your installer, how it signals your unit and whether the unit stays on its normal speed below the setting.
A Danish study ran a bedroom fan from about 900 ppm and the nights still averaged 835, so a control has to start below the goal. Good home CO2 sensors are rated within about 55 to 90 ppm at 800, and the night average includes the climb after bedtime, so 750 on and 650 off leaves room for both. A control in the return duct mixes the bedroom with empty rooms, so it needs lower settings still (about 650 on, 550 off), and your monitor in the bedroom has the final word. These are HouseExhale’s numbers: no study has tested a control against an 800 night average yet.
What it works with
Documented for: S&P TRC and TRPLe (S&P’s July 2022 brochure).
Specs
- Range
- 600–2,000 ppm, adjustable
- Power
- 24 V AC
- Listed for
- S&P TRC and TRPLe
From the maker’s documents, read October 17, 2026. Prices are before tax and shipping and change often.
Made by the ventilator’s maker
Sold for a maker’s own units, with the wiring in its manuals. An installer fits them.

Fantech CO2RT-R (item 99315)
Setting range not published
Wall CO2 controller with a relay

RenewAire CO2-W (wall) and CO2-D (duct)
Can be set under 800
CO2 controller with a relay, for RenewAire ERVs

Zehnder CO2 sensor (0–10 V) with the Option Box
Can be set under 800
Wall CO2 sensor for ComfoAir units